If you are looking for cost-effectiveness and
reliability don't overlook the best selling measurement unit of all, the
MSR145. This thumb sized datalogger records over 2,000,000 measurement
parameters and is capable of simultaneously measuring and recording the
four primary physical variables temperature, humidity, pressure and
3-axis acceleration/ attitude.
Small device - big performance
The MSR145 is available with two or four optional
analogue inputs that can be used for instance, to connect external
sensors (conductivity, speed). This considerably expands your MSR
datalogger's scope of application allowing you to use the unit
cost-effectively for additional measurement tasks. Also included with
this option are an alarm output and an input for starting and stopping
data recording.
|
 |
| |
MSR145
Standard
|
MSR145WS
Waterproof Standard
|
MSR145W
Waterproof
|
 |
 |
 |
| Size: |
20 x 15 x 52 mm |
20 x 15 x 61 mm |
18 x 14 x 62 mm |
| Weight: |
Approx. 16g |
Approx. 23g |
Approx. 18g |
| Sheath material: |
PC, not encapsulated |
PC, encapsulated |
Silicon, encapsulated |
| Standards: |
Protection Classification
IP 60 |
Protection Classification
IP 67 |
Protection Classification
IP 67 |
| Medium: |
Air |
Air, water |
Air, various liquids |
Technical Specifications for All MSR145 Models
| Measured parameters: |
●
Temperature
● Relative humidity with integrated temperature
● Pressure (e.g. altimeter, water level, barometer)
● 3-axis acceleration (e.. determining position)
● 2 or 4 analogue inputs |
| Working range: |
|
| Temperature: |
-10°C to +58°C
-50°C to +125°C (with optional external sensor) |
| Humidity: |
0-100% relative humidity (-20°C
to +65°C) |
| Pressure: |
0-2,500 mbar absolute
0-14,000 mbar absolute |
| Acceleration: |
±10G / ±2G
selectable |
| Accuracy: |
|
| Temperature: |
±0.1°C (+5°C to
+45°C)
±0.2°C (-10°C to +58°C) |
| Humidity: |
±2% rel. humidity
(10-85% rel. humidity, 0°C to +40°C)
±4% rel. humidity (85-95% rel. humidity, 0°C to +40°C) |
| Pressure: |
±2.5 mbar (750-1100
mbar absolute) |
| Acceleration: |
±0.15G (25°C) |
| Storage Rate: |
|
| Temperature and Humidity: |
1/s to 12/h |
| Pressure: |
10/s to 12/h |
| Acceleration Analogue: |
50/s to 12/h |
| Memory Capacity: |
Over 2,000,000 measurement parameters |
| Key: |
Set bookmark or start and stop
recording |
| LED: |
|
| Blue: |
Record indicator |
| Red: |
Alarm indicator |
| Yelow: |
Battery charge indicator |
| Power Supply: |
Rechargeable lithium polymer battery
170 mAh. The battery is charged via the USB connection. One battery
charge is sufficient for operation of the unit for several months
(measurement rate 1.minute) |
| Interface: |
USB |
| Operating Conditions: |
| Temperature: |
-20°C to +65°C |
| Pressure: |
500 mbar to 2,500 mbar absolute |
| Optimum Storage
Conditions: |
| Temperature: |
-+5°C to +45°C
(ideal storage conditions for the battery) |
| Humidity: |
10-95% relative humidity,
non-condensing |
| Standards: |
The MR145 complies with EU Directive
RoHS / WEEE |
|