Introduction
In this experiment students follow a familiar titration procedure, but using the Go Direct pH Sensor, rather than an indicator, to determine the endpoint. By taking event-based readings, a graph of pH against volume is produced and a precise volume determined at pH 7.0, the equivalence point.
Techniques/skills covered (taken from AQA GCSE Chemistry 8462):
- AT 3: Use of appropriate apparatus and techniques for conducting and monitoring chemical reactions, including appropriate reagents and/or techniques for the measurement of pH in different situations.
- Required practical activity 2: determination of the reacting volumes of solutions of a strong acid and a strong alkali by titration
Method
Position the burette above the magnetic stirrer, such that there is enough clearance to place the beaker under the burette. Fill the burette with standard HCl solution. With the pipette, add 25.0 cm3 of NaOH solution to the beaker. Attach the Vernier Microstirrer to the end of the Vernier Go Direct pH Sensor and place in the beaker, supported by either the Vernier Electrode Support or a loosely-fitted clamp. If using the magnetic stirrer, observe that the Microstirrer paddle is turning freely.
Apparatus
For Titration
- 50 cm3 burette
- 25 cm3 glass pipette
- 150 cm3 glass beaker
- standard HCl solution
- NaOH solution of unknown concentration
For Measurement and Analysis
- Vernier Go Direct pH Sensor and Electrode Support or clamp and clamp stand.
- Magnetic stirrer and Vernier microstirrer
- Graphical Analysis app on Windows, Mac OS or mobile device or Graphical Analysis web app on Chromebook, Windows or Mac OS