AQA GCSE Chemistry Measuring Concentration by Titration, Drop-Counter Method

Introduction
In this experiment, students follow a familiar titration procedure, but using both the Go Direct pH Sensor and the Go Direct Drop Counter, to determine the equivalence point of a titration. Once set up and initiated, data is collected in real time, and a graph of pH vs volume of reagent added is generated.
Techniques/Skill Covered (taken from AQA GCSE Chemistry 8462):
- AT 3: Use of appropriate apparatus and techniques for conducting and monitoring chemical reactions, including appropriate reagents and/or techniques for the measurement of pH in different situations.
- Required practical activity 2: determination of the reacting volumes of solutions of a strong acid and a strong alkali by titration
Method
Attach the Go Direct Drop Counter to a retort stand, just above the mouth of the beaker, with the Go Direct pH Probe dropped through the hole at the end, so that the bottom of the probe is flush with the base of the beaker. (If using the microstirrer, check that the paddle is turning freely.) Clamp the plastic reagent reservoir so that the tap is directly above the drop counter’s sensor. Fill the reservoir with standard HCl solution, ensuring that both taps are closed.
Apparatus
For titration
- Plastic reagent reservoir
- Plastic valve with double stopcock fitting
- 25 cm³ glass pipette
- 150 cm³ glass beaker
- standard HCl solution
- NaOH solution of unknown concentration
For measurement and analysis
- Vernier Go Direct pH Sensor
- Vernier Go Direct® Drop Counter
- Magnetic stirrer and Vernier microstirrer
- Graphical Analysis app on Windows, Mac OS or mobile device or Graphical Analysis web app on Chromebook, Windows or Mac OS
Would you like the full experiment?