| Overload capacity FDA612SR: FDA602S2K: | max. 1.5 times final valve maximum 250 mbar |
| Accuracy (zero-pt adjusted) | ±0.5% of final value in range 0 to positive final value |
| Common mode pressure: | FDA602S2K max. 700 mbar FDA612SR max. 3 bar |
| Nominal temperature: | 25°C |
| Temperature drift FDA612SR compensated temperature range: FDA602S2K: compensated temperature range: | < ±1.5 % of final value 0 to +60°C < ±2 % of final value -10 to +60°C |
| Operating range: | -10 to +60 °C, 10 to 90% RH, non-condensing |
| Dimensions: | 74 x 20 x 8.8mm |
| Hose terminals: | Ø 5 mm, 12 mm long |
| Sensor material: | aluminium, nylon, silicone, silica gel, brass |
| Including one set of 2m silicone hoses, pressure measuring connector and manufacturers test certificate | |
|---|---|
| Measuring Range ± 100mbar Measured Variables mbar | FDA612SR |
| Measuring Range ± 250Pa.Measured Variables m/s | FDA602S2K |
| Measuring Range ± 1250Pa ( 1 to 40m/s) Measured Variables m/s, Pa | FDA602S1K |
| Measuring Range ± 6800Pa ( 2 to 90m/s) Measured Variables m/s, Pa | FDA602S6K |