Technical Specification
| TECHNICAL DATA: | |
|---|---|
| Precision class | AA |
| Measuring rate | (100), 50, 10 and 2.5 mops |
| Measuring inputs Electrical isolation Option GT | 5 ALMEMO®-input sockets with semiconductor relays (50V) for analogue sensors Additional electrical isolation between measuring inputs and power supply (device ground) |
| Additional channels | 4 function channels, device-internal |
| Sensor power supply Rechargeable battery pack Mains adapter | 6/9/12 V, max. 0.5A; Mains adaptor 12 V, maximum 0.5 A |
| Atmospheric pressure sensor Measuring range Accuracy | Integrated 700 to 1100 mbar ±2.5 mbar (at 23 °C ±5 K) |
| Outputs | 2 ALMEMO® sockets for all output modules (analog, data, trigger, relay cables, memory etc.) |
| Graphic Display | 128 x 128 pixels, 16 rows. Illumination: 5 white LEDs, 3 brightness levels |
| Keypad | 9 tactile silicone keys (of which, 4 soft keys) |
| Memory | EEPROM sufficient for 200,000 measured values |
| Date and time-of-day | Real-time clock, buffered with battery |
| Power supply Rechargeable battery/ies Mains adapter DC adapter cable | 3 AA batteries NiMH or alkaline integrated, high-speed charging (2.5 hours) ZA1312NA12 100 to 240 VAC to 12 VDC, 1.5 A electrically isolated electrically isolated ZA2690-UK2 10 to 30 V, 1 A |
| Current consumption (without input and output modules) Active mode With illumination Sleep mode | approx. 17 mA approx. 25 to 140 mA approx. 0.05 mA |
| Housing | 209 x 107 x 54 mm (LxWxH) ABS, 570 g |
| Click here for other technical details. | |