Technical Specification
| Gas: | CO |
| Measuring principle: | electrochemical reaction |
| Measuring range: | see types |
| Zero point error: | < 10 ppm CO |
| Gauge reading balance: | < 3 ppm CO |
| Error of meas. value: | ±3% of full scale value |
| Zero point drift: | < 2% (1 year) |
| Reproducibility: | < 2% (1 year) |
| Linearity: | < 2% of full scale value |
| Settling time t90: | < 60s |
| Transverse sensitivity: | < 2% by integrated filter |
| Nominal conditions: | 20 °C, 50 % r.H., 1013 mbar |
| Operating conditions: | –10 to +40°C, sensor in range temperature compensated > 15 to 90 % r.H. non-condensing |
| Life span of the meas. cell: | approx. 2 years typical |
| Output: | 4 to 20 mA on ALMEMO® connector |
| Supply voltage: | 24V via ALMEMO® connector |
| Dimensions of meas. head: | Ø 80mm, height 80mm |
| Weight: | 600g |
| Connecting cable: | 1.5m, with ALMEMO® connector |