Technical Specification
| Wind Velocity | |
| Measuring method | Ultrasonic |
| Measuring range | 0 to 75 m/s |
| Resolution | 0.1 m/s |
| Accuracy | 0 to 35 m/s: ±0.3 m/s RMS or ±3 % RMS. >35 m/s: ±5 RMS |
| Response threshold | 0.3 m/s |
| Sampling rate | 10 seconds |
| ALMEMO® D7 quantities | Average value, minimum value, maximum value (at output cycle) |
| Wind Direction | |
| Measuring method | Ultrasonic |
| Measuring range | 0 to 359.9 ° |
| Resolution | 0.1 degrees |
| Accuracy | 1 m/s) |
| Response threshold | 0.3 m/s |
| Sampling rate | 10 seconds |
| ALMEMO® D7 quantities | Average value, minimum value, maximum value, average value as text (at output cycle) |
| Precipitation, rainfall | |
| Measuring method | Radar sensor |
| Measuring range | Drop size 0.3 to 5.0 mm |
| Resolution | Precipitation, liquid 0.01 mm |
| Precipitation types | rain, snow |
| Reproducibility | typical >90 % |
| Response threshold | 0.002 mm |
| Sampling rate | On reaching the response threshold, event-dependent |
| Rainfall intensity | 0 to 200 mm/h; Sampling rate 1 minute |
| ALMEMO® D7 quantities | Rainfall quantity or snow quantity (at the output cycle) Rainfall intensity or snow intensity, current momentary value |
| Air temperature | |
| Measuring method | NTC |
| Measuring range | -50 to +60 °C |
| Resolution | 0.1 K (-20 to +50 °C), otherwise 0.2 K |
| Accuracy sensor | ±0.2 K (-20 to +50 °C), otherwise ±0.5 K (>-30 °C) |
| Sampling rate | 1 minute |
| ALMEMO® D7 quantities | Current momentary value, average value, minimum value, maximum value (at output cycle) |
| Atmospheric humidity | |
| Measuring method | capacitive |
| Measuring range | 0 to 100 % RH |
| Resolution | 0.1 % RH |
| Accuracy sensor | ±2 % RH |
| Sampling rate | 1 minute |
| ALMEMO® D7 quantities | Current momentary value |
| Atmospheric pressure | |
| Measuring method | MEMS sensor, capacitive |
| Measuring range | 300 to 1200 hPa |
| Resolution | 0.1 hPa |
| Accuracy sensor | ±0.5 hPa (0 to +40 °C) |
| Sampling rate | 1 minute |
| ALMEMO® D7 quantities | Current momentary value |
| Operating conditions | |
| Temperature | -50 to +60 °C (with heating) |
| Relative humidity | 0 to 100 % RH |
| Dimensions (including fixture) | |
| Height | 343 mm |
| Diameter | 150 mm |
| Weight | approx. 1.5 kg (including fixture, excluding connection cables) |
| Housing | Plastic Protective class IP66 |
| Fixture | Mast fixture, stainless steel, for Ø 60 to 76 mm |
| Sensor connector | Built-in plug |
| Sensor connection cable | fitted in connection box Length (see variants, accessories) |
| Connection box | Clamp fitting the sensor connection cable and the ALMEMO® connection cable Plug fitting the mains unit cable for the heating system supply Dimensions 80 x 82 x 55 mm 3 cable glands |
| Heating | |
| Supply voltage | 24 VDC |
| Current consumption | 1.7 A (40 W) via external mains unit ZB1024NA2 (in delivery), 100 to 240 V AC / 24 V DC, 4,17 A with hollow connector, fitted in the connection box |
| ALMEMO® connection cable fitted in connection box | Length = 2 meters |
| ALMEMO® D7 plug | |
| Refresh rate 2 seconds for all current momentary values Average value, maximum value, minimum value and quantities - at the output cycle (minimum 2 sec. up to 24 hours) of the ALMEMO® V7 device | |
| Supply with mains unit 24V (default): All functions available. 24 V from the mains unit, max. 1,8 A. 12 V from ALMEMO® device, typ. 10 mA. Supply without mains unit 24V (mobile operation): Fan and heating deactivated. 12 V from ALMEMO® device, typ. 130 mA with rainfall radar in continuous operation. Operating in Energy Saver mode 1: typ. 25 mA, no rain test / no rain, typ. 130 mA for 2 s / Min in the rain test, typ. 130 mA continuously, in the rain | |