£4,835.00 – £4,976.00
Digital meteorological transducer for measuring wind, precipitation, air temperature, atmospheric humidity, atmospheric pressure. Forced-ventilated radiation-protected housing, integrated heating, bracket for mast fitting. Sensor with built-in plug, including sensor connection cable Length = 10 meters fitted in connection box, external mains unit ZB1024NA2, fitted in the connection box, ALMEMO® connection cable fitted in connection box Length = 2 meters with ALMEMO® D7 plug.
Technical Specification
Wind Velocity | |
Measuring method | Ultrasonic |
Measuring range | 0 to 75 m/s |
Resolution | 0.1 m/s |
Accuracy | ±0.3 m/s or ±3 % (0 to 35 m/s) ±5 % (>35 m/s) RMS |
Response threshold | 0.3 m/s |
Sampling rate | 10 seconds |
ALMEMO® D7 quantities | Average value, minimum value, maximum value (at output cycle) |
Wind Direction | |
Measuring method | Ultrasonic |
Measuring range | 0 to 359.9 ° |
Resolution | 0.1 degrees |
Accuracy | <3 ° (>1 m/s) |
Response threshold | 0.3 m/s |
Sampling rate | 10 seconds |
ALMEMO® D7 quantities | Average value, minimum value, maximum value, average value as text (at output cycle) |
Precipitation, rainfall | |
Measuring method | Radar sensor |
Measuring range | Drop size 0.3 to 5.0 mm |
Resolution | Precipitation, liquid 0.01 mm |
Precipitation types | rain, snow |
Reproducibility | typical >90 % |
Response threshold | 0.002 mm |
Sampling rate | On reaching the response threshold, event-dependent |
Rainfall intensity | 0 to 200 mm/h; Sampling rate 1 minute |
ALMEMO® D7 quantities | Rainfall quantity or snow quantity (at the output cycle) Rainfall intensity or snow intensity, current momentary value |
Air temperature | |
Measuring method | NTC |
Measuring range | -50 to +60 °C |
Resolution | 0.1 K (-20 to +50 °C), otherwise 0.2 K |
Accuracy sensor | ±0.2 K (-20 to +50 °C), otherwise ±0.5 K (>-30 °C) |
Sampling rate | 1 minute |
ALMEMO® D7 quantities | Current momentary value, average value, minimum value, maximum value (at output cycle) |
Atmospheric humidity | |
Measuring method | capacitive |
Measuring range | 0 to 100 % RH |
Resolution | 0.1 % RH |
Accuracy sensor | ±2 % RH |
Sampling rate | 1 minute |
ALMEMO® D7 quantities | Current momentary value |
Atmospheric pressure | |
Measuring method | MEMS sensor, capacitive |
Measuring range | 300 to 1200 hPa |
Resolution | 0.1 hPa |
Accuracy sensor | ±0.5 hPa (0 to +40 °C) |
Sampling rate | 1 minute |
ALMEMO® D7 quantities | Current momentary value |
Operating conditions | |
Temperature | -50 to +60 °C (with heating) |
Relative humidity | 0 to 100 % RH |
Dimensions (including fixture) | |
Height | 343 mm |
Diameter | 150 mm |
Weight | approx. 1.5 kg (including fixture, excluding connection cables) |
Housing | Plastic Protective class IP66 |
Fixture | Mast fixture, stainless steel, for Ø 60 to 76 mm |
Sensor connector | Built-in plug |
Sensor connection cable | fitted in connection box Length (see variants, accessories) |
Connection box | Clamp fitting the sensor connection cable and the ALMEMO® connection cable Plug fitting the mains unit cable for the heating system supply Dimensions 80 x 82 x 55 mm 3 cable glands |
Heating | |
Supply voltage | 24 VDC |
Current consumption | 1.7 A (40 W) via external mains unit ZB1024NA2 (in delivery), 100 to 240 V AC / 24 V DC, 4,17 A with hollow connector, fitted in the connection box |
ALMEMO® connection cable fitted in connection box | Length = 2 meters |
ALMEMO® D7 plug | |
Refresh rate 2 seconds for all current momentary values Average value, maximum value, minimum value and quantities - at the output cycle (minimum 2 sec. up to 24 hours) of the ALMEMO® V7 device | |
Supply with mains unit 24V (default): All functions available. 24 V from the mains unit, max. 1,8 A. 12 V from ALMEMO® device, typ. 10 mA. Supply without mains unit 24V (mobile operation): Fan and heating deactivated. 12 V from ALMEMO® device, typ. 130 mA with rainfall radar in continuous operation. Operating in Energy Saver mode 1: typ. 25 mA, no rain test / no rain, typ. 130 mA for 2 s / Min in the rain test, typ. 130 mA continuously, in the rain |
Technical Features
Digital meteorological transducer for operating with ALMEMO® V7 devices
This digital meteorological transducer, with its integrated signal processor or A/D converter, can acquire all important weather variables in one device (over 20 different measurable variables). Up to 10 measuring channels can be evaluated simultaneously via the ALMEMO® D7 plug.
On leaving our factory the following variables are programmed : wind velocity (m/s), wind direction (°), precipitation quantity (mm), precipitation intensity (mm/h), air temperature (°C), relative atmospheric humidity (% RH), barometric atmospheric pressure (hPa).
The meteorological transducer operates with current ALMEMO® V7 devices, including precision measuring instrument ALMEMO® 710 and professional measuring instrument ALMEMO® 202.
For professional applications
The meteorological transducer complies in essence with all specifications laid down by the WMO (world meteorological organization) and is used in a wide variety of areas, e.g. weather services, water management, transport technology (roads, rail), agriculture, renewable energy technology, and the monitoring of air quality and atmospheric emissions.
The transducer can be fitted quickly and easily, e.g. on a mast or pole, using the supplied bracket.
The connection cable can be plugged onto the transducer. In the small connection box the signal cables are clamped and the mains unit 24V for the heating system supply are plugged. In mobile use (without mains unit 24V) heating and fan (see below) are deactivated, and the rainfall radar (see below) can be operated in Energy Saver mode. 1
Wind
Wind is measured by means of four ultrasonic sensors (the four main compass points). From the runtime differences the wind velocity is calculated in m/s and the wind direction in °.
This measuring procedure is maintenance-free (no moving parts). For operation in winter the ultrasonic sensors can if so required be heated.
Precipitation, rainfall
Precipitation is acquired using tried and tested radar technology. A Doppler radar measures the velocity of individual drops of rain / snow. Precipitation quantity (in mm) and precipitation intensity (in mm/h) can be calculated on the basis of the correlation of drop size and drop velocity. The type of precipitation (rain / snow) is determined on the basis of the different velocity of descent. This measuring procedure is maintenance-free (no moving parts).
For operation in winter the precipitation sensor can if so required be heated.
Air temperature and atmospheric humidity
Air temperature is measured (in °C) by means of a high-precision NTC resistance sensor; relative atmospheric humidity is measured (in % RH) by means of a capacitive humidity sensor. These sensors are enclosed in a forced-ventilated radiation-protected housing in order to minimize external influences (e.g. solar radiation, etc.). This ensures that in spite of high solar radiation accurate measuring results can still be achieved. The forced ventilation,
similarly, improves responsiveness in the event of condensation.
Atmospheric pressure
Absolute atmospheric pressure is measured (in hPa) by means of an integrated sensor.
Measured values
The sensors in the meteorological transducer measure the current measured values continuously and at their internal sampling rate. In the ALMEMO® D7 plug the minimum / maximum / average values and quantities are calculated (at the output cycle of the ALMEMO® V7 device); this is for the purpose of various measurable variables.