Navigation

Go Direct® Air Quality Sensor

Go Direct® Air Quality Sensor

£349.00 ex VAT | £418.80 Inc VAT

The Go Direct Air Quality Sensor helps students investigate real‑world questions about the quality of the air we breathe with measurable evidence—right where they live and learn.

Designed for high school and college use, this durable sensor supports indoor and outdoor monitoring so students can track pollutants over time, analyze spatial patterns, and connect air quality to human and ecological health.

Available to Order

Contact via Whatsapp 01530 832500

Description

Make air quality tangible, local, and measurable for students. The Go Direct Air Quality Sensor transforms air quality from an abstract concept into measurable evidence in a classroom-ready form. It equips educators and students with the tools needed to investigate pollution scientifically, think systemically, and understand how environmental conditions directly affect human and ecological health—right where they live and learn.

Extended Investigation Ideas

  • Compare indoor and outdoor air quality.
  • Monitor particulate matter near roads, parking lots, or green spaces.
  • Analyze air quality changes during traffic peaks or daily weather shifts.
  • Observe ozone trends on sunny vs. cloudy days.
  • Investigate how different types of cooktops affect CO2 and PM levels.

Measures Key Air Pollutants

  • Particulate Matter (PM1, PM2.5, and PM10)
  • Ground-Level Ozone (O3)
  • Nitrogen Dioxide (NO2)
  • Sulfur Dioxide (SO2)
  • Carbon Dioxide (CO2)
  • Volatile Organic Compound Index (VOC Index)

Measures Environmental Conditions

  • Temperature
  • Relative Humidity
  • Barometric and Station Pressure

Key Features

  • Real-time air quality data collection via Bluetooth® wireless technology
  • Remote data logging for long-term or remote investigations, no connection required
  • Integrated Global Navigation Satellite System (GNSS) allows for geotagging
  • Durable for indoor and outdoor use

Remote Data Logging—Go Beyond Wireless Limits!

This Go Direct sensor is capable of remote data logging! This feature allows sensors to store data directly to their internal memory—ideal for investigations that extend beyond typical connection ranges like long-term environmental monitoring or rocket launches. It works seamlessly with our award-winning Vernier Graphical Analysis® app so students can visualize their data and make key connections between abstract science concepts and real-world phenomena.

Rechargeable Battery—Ready When You Are

The robust rechargeable battery offers long battery life and provides always-ready operation when using the sensor wirelessly. Monitor battery life directly from our award-winning Vernier Graphical Analysis® app, as well as LabQuest® 3. Should the battery run low, simply connect the sensor to the charging cable and keep on collecting—no interruptions or inconvenience to you or your students.

Wireless or Wired—The Flexibility to Choose

Our Go Direct sensors connect directly to your mobile device, Chromebook, or computer using our Vernier Graphical Analysis® app—no additional equipment or software purchases are necessary. Go Direct sensors can be used wired via USB or wirelessly via Bluetooth® wireless technology, allowing you to choose the best solution for your classroom or laboratory.

Specification

Go Direct Air Quality has the following channels

  • PM1.0
  • PM2.5
  • PM10
  • CO2
  • NO2
  • SO2
  • O3
  • VOC Index
  • Temperature
  • Relative Humidity
  • Barometric Pressure
  • Station Pressure
  • Latitude
  • Longitude
  • Altitude

Specifications

  • PM Mass Concentration Specified Range: 0–1000 µg/m3
    • PM1 size range: 0.3–1µg
    • PM2.5 size range: 0.3–2.5µg
    • PM10 size range: 0.3–10µg
  • CO2 Range: 0–5,000 ppm
  • NO2 Range: 0-2000ppb
  • SO2 Range: 0-2000ppb
  • O3 Range: 0-2000ppb
  • VOC Index: 1–500
  • Temperature Range: 10–40℃ (-10℃ min, 50℃ max short term)
  • Relative Humidity Range: 20–80% (10% min, 90% max short term)
  • Station Pressure Range: 260–1260hPa
  • Maximum sampling rate: 1 sample/s

Experiments

Included Lessons

Easily incorporate data collection into your curriculum with student instructions and essential instructor information for each of the following experiments. These lessons are aligned with AP standards and Next Generation Science Standards (NGSS).

  • Using the Sensor: Learn different channels, remote data collection, and basic analysis.
  • Indoor Air Quality Investigation: Analyze indoor air quality data and develop recommendations to improve it.
  • Traffic and Outdoor Air Quality: Investigate how vehicle traffic influences air pollution.

Requirements

Software Requirements

InterfaceLabQuest App
LabQuest 3Full Support
LabQuest 2
(Discontinued)
Full Support 1
Vernier LabQuest
(Discontinued)
Incompatible

COMPATIBILITY NOTES

  1. Wireless connection of this sensor to a LabQuest 2 requires a Go Direct Bluetooth Adapter when used with some older LabQuest 2 models.

]

InterfaceGraphical Analysis App for Computers
NO INTERFACE REQUIREDFull support 1
LabQuest 3Full support 2
LabQuest 2
(Discontinued)
Full support 2 3

COMPATIBILITY NOTES

  1. For Bluetooth® connectivity, only computers running Windows 10 or Mac OS X 10.10 or newer are supported. The computer must also have a compatible Bluetooth 4.0+ radio.
  2. Connect this sensor directly to a computer or Chromebook via a USB or wireless Bluetooth® connection for best results. Alternatively, this sensor is fully supported when used with LabQuest 2 or LabQuest 3 when the LabQuest is connected to a computer or Chromebook via Wireless Data Sharing.
  3. Wireless connection of this sensor to a LabQuest 2 requires a Go Direct Bluetooth Adapter when used with some older LabQuest 2 models.

InterfaceGraphical Analysis for Chrome
NO INTERFACE REQUIREDFull Support
LabQuest 3

Full Support 1
LabQuest 2
(Discontinued)
Full Support 1 2

COMPATIBILITY NOTES

  1. Connect this sensor directly to a computer or Chromebook via a USB or wireless Bluetooth® connection for best results. Alternatively, this sensor is fully supported when used with LabQuest 2 or LabQuest 3 when the LabQuest is connected to a computer or Chromebook via Wireless Data Sharing.
  2. Wireless connection of this sensor to a LabQuest 2 requires a Go Direct Bluetooth Adapter when used with some older LabQuest 2 models.

InterfaceSoftware
Graphical Analysis for iOS
NO INTERFACE REQUIREDFull Support
LabQuest 3Full Support 1 2
LabQuest 2
(Discontinued)
Full Support 1 2 3

COMPATIBILITY NOTES

  1. Connect this sensor directly to a supported mobile device via a wireless Bluetooth® connection for best results.
  2. Mobile devices can only connect to LabQuest 2 or LabQuest 3 via Wireless Data Sharing.
  3. Wireless connection of this sensor to a LabQuest 2 requires a Go Direct Bluetooth Adapter when used with some older LabQuest 2 models.

InterfaceSoftware
Graphical Analysis for Android
NO INTERFACE REQUIREDFull Support
LabQuest 3Full Support 1 2
LabQuest 2
(Discontinued)
Full Support 1 2 3

COMPATIBILITY NOTES

  1. Connect this sensor directly to a supported mobile device via a wireless Bluetooth® connection for best results.
  2. Mobile devices can only connect to LabQuest 2 or LabQuest 3 via Wireless Data Sharing.
  3. Wireless connection of this sensor to a LabQuest 2 requires a Go Direct Bluetooth Adapter when used with some older LabQuest 2 models.

What's Included

  • Go Direct Air Quality Sensor
  • Sensor Bracket for Go Direct
  • Vernier Lanyard