£94.00 ex VAT | £112.80 Inc VAT
The Go Direct Ion-Selective Electrode Amplifier is a mV and mg/L amplifier that connects to Vernier Ion-Selective Electrodes and compatible third-party BNC ion-selective electrodes. It connects via Bluetooth®wireless technology or wired via USB to your device.
Available to Order
Description
Expand your water quality, environmental, and agriculture experiment options with the wireless Go Direct Ion-Selective Electrode Amplifier. The versatile BNC connector allows students to easily remove and attach various ion-selective electrodes, such as the Go Direct Nitrate Ion-Selective Electrode, Go Direct Ammonium Ion-Selective Electrode, Go Direct Calcium Ion-Selective Electrode, Go Direct Chloride Ion-Selective Electrode, or Go Direct Potassium Ion-Selective Electrode.
Because the Go Direct Ion-Selective Electrode Amplifier is compatible with third-party electrodes, students learn consistent calibration and handling techniques on one amplifier using one software program. When an electrode expires or becomes damaged, you need only replace the electrode and not the entire sensor—lowering your overall equipment costs.
Rechargeable Battery—Ready When You Are
The robust rechargeable battery offers long battery life and provides always-ready operation. Monitor battery life directly from our free Graphical Analysis™ 4 app. Should the battery run low, simply connect the sensor to the charging cable and keep on collecting—no interruptions or inconvenience to you or your students.
Wired or Wireless—The Flexibility to Choose
Our Go Direct sensors connect directly to your mobile device, Chromebook™, or computer using our free Graphical Analysis™ 4 app—no additional equipment or software purchases are necessary. Go Direct sensors can be used wired via USB or wirelessly via Bluetooth® wireless technology, allowing you to choose the solution best for your classroom or laboratory.
Important: Ion-Selective Electrodes require good chemical technique and careful calibration to obtain accurate results; they are not recommended for middle school or elementary students.
Specification
- Units: mV or mg/L
- Input range (mV): ±1000 mV
- Connections:
- Wireless: Bluetooth
- Wired: USB
Compatibility Requirements
Go Direct™ Sensors are partially compatible with LabQuest 2 (version 2.8.1), a standalone data logger with built-in graphing and analysis software. Please see the compatibility notes below for details.
Learn more about LabQuest 2 »
Interface | Graphical Analysis for Computers VERSION 4.4 |
---|---|
NO INTERFACE REQUIRED | Full support 12 |
LABQUEST 2 | Full support 34 |
COMPATIBILITY NOTES
- Requires a BNC electrode
- For Bluetooth® connectivity, only computers running Windows 10 or Mac OS X 10.10 or newer are supported. The computer must also have a compatible Bluetooth 4.0+ radio.
- Connect this sensor directly to a computer or Chromebook via a USB or wireless Bluetooth® connection for best results. Alternatively, this sensor is fully supported when used with LabQuest 2 when LabQuest 2 is connected to a computer or Chromebook via Wireless Data Sharing.
- Wireless connection of this sensor to a LabQuest 2 requires a Go Wireless Bluetooth Adapter when used with some older LabQuest 2 models.
Interface | Graphical Analysis for Chrome VERSION 4.4 |
---|---|
NO INTERFACE REQUIRED | Full Support 1 |
LABQUEST 2 | Full Support 23 |
COMPATIBILITY NOTES
- Requires a BNC electrode
- Connect this sensor directly to a computer or Chromebook via a USB or wireless Bluetooth® connection for best results. Alternatively, this sensor is fully supported when used with LabQuest 2 when LabQuest 2 is connected to a computer or Chromebook via Wireless Data Sharing.
- Wireless connection of this sensor to a LabQuest 2 requires a Go Wireless Bluetooth Adapter when used with some older LabQuest 2 models.
Interface | Software |
---|---|
Graphical Analysis 4 for iOS | |
NO INTERFACE REQUIRED | Full Support1 |
LABQUEST 2 | Full Support 234 |
COMPATIBILITY NOTES
- Requires a BNC electrode
- Connect this sensor directly to a supported mobile device via a wireless Bluetooth® connection for best results.
- Mobile devices can only connect to LabQuest 2 via Wireless Data Sharing.
- Wireless connection of this sensor to a LabQuest 2 requires a Go Wireless Bluetooth Adapter when used with some older LabQuest 2 models.
Interface | Software | |
---|---|---|
Graphical Analysis for Android | Graphical Analysis GW for Android | |
NO INTERFACE REQUIRED | Full Support1 | Incompatiable1 |
LABQUEST 2 | Full Support 234 | Full Support 34 |
COMPATIBILITY NOTES
- Requires a BNC electrode
- Connect this sensor directly to a supported mobile device via a wireless Bluetooth® connection for best results.
- Mobile devices can only connect to LabQuest 2 via Wireless Data Sharing.
- Wireless connection of this sensor to a LabQuest 2 requires a Go Wireless Bluetooth Adapter when used with some older LabQuest 2 models.
BNC Electrodes
- Go Direct Nitrate Ion-Selective Electrode
- Go Direct Ammonium Ion-Selective Electrode
- Go Direct Calcium Ion-Selective Electrode
- Go Direct Chloride Ion-Selective Electrode
- Go Direct Potassium Ion-Selective Electrode
For our full list of BNC electrodes, please click here.