Navigation

Go Direct® Optical Dissolved Oxygen Probe

Go Direct® Optical Dissolved Oxygen Probe

£499.00 ex VAT | £598.80 Inc VAT

The Go Direct Optical Dissolved Oxygen Probe makes it easy to measure dissolved oxygen concentration, water temperature, and atmospheric pressure. It connects wirelessly via Bluetooth® or wired via USB to your device.

Available to Order

Contact via Whatsapp 01530 832500

Description

The Go Direct Optical Dissolved Oxygen Probe combines the power of multiple sensors to measure dissolved oxygen, water temperature, and atmospheric pressure. Ideal for experiments in biology, ecology, and environmental science courses, the Go Direct Optical Dissolved Oxygen Probe uses luminescent technology to provide fast, easy, and accurate results. Perfect for the field or for the laboratory, this probe requires no calibration, no filling solution, no warm-up time, and no stirring.

This waterproof probe is ready to sample dissolved oxygen immediately without additional setup or the need to warm it up—so more class time can be spent on the investigation.

The Go Direct Optical Dissolved Oxygen Probe can be used in a variety of experiments:

  • Investigate the relationship between temperature and dissolved oxygen in water.
  • Measure primary productivity or biological/biochemical oxygen demand.
  • Explore the interdependence of plants and animals.
  • Monitor watersheds over time.

Rechargeable Battery – Ready when you are

The Go Direct robust rechargeable battery offers long battery life and provides always-ready operation. Monitor battery life directly from our free Graphical Analysis™ app. Should the battery run low, simply connect the sensor to the charging cable and keep on collecting—no interruptions or inconvenience to you or your students.

Wired or Wireless – The Flexibility to Choose

Our Go Direct sensors connect directly to your mobile device, Chromebook™, or computer using our free Graphical Analysis™ app—no additional equipment or software purchases are necessary. Go Direct sensors can be used wired via USB or wirelessly via Bluetooth, allowing you to choose the solution best for your classroom or laboratory.

Specification

  • Range: 0 to 20 mg/L, 0 to 300%
  • Accuracy mg/L: ±0.2 mg/L below 10 mg/L, ±0.4 mg/L above 10 mg/L
  • Accuracy %: ±2% below 100%, ±5% above 100%
  • Response time: 90% of final reading in 40 seconds
  • Temperature Range: automatic from 0 to 50°C
  • Pressure Range: automatic from 228 mmHg to 1519 mmHg
  • Minimum sample flow: none required

Experiments

Biology with Vernier

  • Interdependence of Plants and Animals
  • Aerobic Respiration
  • Dissolved Oxygen in Water
  • Watershed Testing
  • Physical Profile of a Lake
  • Primary Productivity

Requirements

Software Requirements

InterfaceLabQuest App
LabQuest 3Full Support
LabQuest 2
(Discontinued)
Full Support 1
Vernier LabQuest
(Discontinued)
Incompatible

COMPATIBILITY NOTES

  1. Wireless connection of this sensor to a LabQuest 2 requires a Go Direct Bluetooth Adapter when used with some older LabQuest 2 models.

]

InterfaceGraphical Analysis App for Computers
NO INTERFACE REQUIREDFull support 1
LabQuest 3Full support 2
LabQuest 2
(Discontinued)
Full support 2 3

COMPATIBILITY NOTES

  1. For Bluetooth® connectivity, only computers running Windows 10 or Mac OS X 10.10 or newer are supported. The computer must also have a compatible Bluetooth 4.0+ radio.
  2. Connect this sensor directly to a computer or Chromebook via a USB or wireless Bluetooth® connection for best results. Alternatively, this sensor is fully supported when used with LabQuest 2 or LabQuest 3 when the LabQuest is connected to a computer or Chromebook via Wireless Data Sharing.
  3. Wireless connection of this sensor to a LabQuest 2 requires a Go Direct Bluetooth Adapter when used with some older LabQuest 2 models.

InterfaceGraphical Analysis for Chrome
NO INTERFACE REQUIREDFull Support
LabQuest 3

Full Support 1
LabQuest 2
(Discontinued)
Full Support 1 2

COMPATIBILITY NOTES

  1. Connect this sensor directly to a computer or Chromebook via a USB or wireless Bluetooth® connection for best results. Alternatively, this sensor is fully supported when used with LabQuest 2 or LabQuest 3 when the LabQuest is connected to a computer or Chromebook via Wireless Data Sharing.
  2. Wireless connection of this sensor to a LabQuest 2 requires a Go Direct Bluetooth Adapter when used with some older LabQuest 2 models.

InterfaceSoftware
Graphical Analysis for iOS
NO INTERFACE REQUIREDFull Support
LabQuest 3Full Support 1 2
LabQuest 2
(Discontinued)
Full Support 1 2 3

COMPATIBILITY NOTES

  1. Connect this sensor directly to a supported mobile device via a wireless Bluetooth® connection for best results.
  2. Mobile devices can only connect to LabQuest 2 or LabQuest 3 via Wireless Data Sharing.
  3. Wireless connection of this sensor to a LabQuest 2 requires a Go Direct Bluetooth Adapter when used with some older LabQuest 2 models.

InterfaceSoftware
Graphical Analysis for Android
NO INTERFACE REQUIREDFull Support
LabQuest 3Full Support 1 2
LabQuest 2
(Discontinued)
Full Support 1 2 3

COMPATIBILITY NOTES

  1. Connect this sensor directly to a supported mobile device via a wireless Bluetooth® connection for best results.
  2. Mobile devices can only connect to LabQuest 2 or LabQuest 3 via Wireless Data Sharing.
  3. Wireless connection of this sensor to a LabQuest 2 requires a Go Direct Bluetooth Adapter when used with some older LabQuest 2 models.