Navigation

Go Direct® Pyranometer

Go Direct® Pyranometer

£450.00 ex VAT | £540.00 Inc VAT

The Go Direct Pyranometer measures the power of electromagnetic radiation in watts per square meter. It is sensitive to near infrared, visible, and UV radiation, where 90% of solar energy is concentrated. This probe connects via Bluetooth® wireless technology or via USB to your device.

Available to order

Contact via Whatsapp 01530 832500

Description

The Go Direct Pyranometer measures the power of electromagnetic radiation. It is sensitive to near infrared, visible, and UV radiation, where 90% of solar energy is concentrated. It reads in watts per square meter, so it is great for experiments with solar cells and calculating their efficiency.

It has a weatherproof sensor head with a dome-shape top to allow it to handle a wide range of sun angles.

Rechargeable Battery—Ready When You Are
The robust rechargeable battery offers long battery life and provides always-ready operation when using the sensor wirelessly. Monitor battery life directly from our award-winning Vernier Graphical Analysis® app, as well as LabQuest® 3. Should the battery run low, simply connect the sensor to the charging cable and keep on collecting—no interruptions or inconvenience to you or your students.

Wireless or Wired—The Flexibility to Choose
Our Go Direct sensors connect directly to your mobile device, Chromebook™, or computer using our Vernier Graphical Analysis® app—no additional equipment or software purchases are necessary. Go Direct sensors can be used wired via USB or wirelessly via Bluetooth® wireless technology, allowing you to choose the best solution for your classroom or laboratory.

Specification

  • Irradiance Range: 0 to 1100 watts/m2 (in full sun)
  • Absolute Accuracy: ±5%
  • Repeatability: ±1%
  • Long-Term Drift: Less than 3% per year
  • Cosine Response:
    • 45° zenith angle: 1%
    • 75° zenith angle: ±5%
  • Wavelength range: 360 nm to 1120 nm
  • Typical Resolution: 0.3 Watts/m2
  • Sensor dimensions:
    • Diameter: 2.4 cm
    • Height: 3.3 cm
    • Cable Length: 5 m
  • Materials: Anodized aluminum with cast acrylic lens

Requirements

Software Requirements

InterfaceLabQuest App
LabQuest 3Full Support
LabQuest 2
(Discontinued)
Full Support 1
Vernier LabQuest
(Discontinued)
Incompatible

COMPATIBILITY NOTES

  1. Wireless connection of this sensor to a LabQuest 2 requires a Go Direct Bluetooth Adapter when used with some older LabQuest 2 models.

]

InterfaceGraphical Analysis App for Computers
NO INTERFACE REQUIREDFull support 1
LabQuest 3Full support 2
LabQuest 2
(Discontinued)
Full support 2 3

COMPATIBILITY NOTES

  1. For Bluetooth® connectivity, only computers running Windows 10 or Mac OS X 10.10 or newer are supported. The computer must also have a compatible Bluetooth 4.0+ radio.
  2. Connect this sensor directly to a computer or Chromebook via a USB or wireless Bluetooth® connection for best results. Alternatively, this sensor is fully supported when used with LabQuest 2 or LabQuest 3 when the LabQuest is connected to a computer or Chromebook via Wireless Data Sharing.
  3. Wireless connection of this sensor to a LabQuest 2 requires a Go Direct Bluetooth Adapter when used with some older LabQuest 2 models.

InterfaceGraphical Analysis for Chrome
NO INTERFACE REQUIREDFull Support
LabQuest 3

Full Support 1
LabQuest 2
(Discontinued)
Full Support 1 2

COMPATIBILITY NOTES

  1. Connect this sensor directly to a computer or Chromebook via a USB or wireless Bluetooth® connection for best results. Alternatively, this sensor is fully supported when used with LabQuest 2 or LabQuest 3 when the LabQuest is connected to a computer or Chromebook via Wireless Data Sharing.
  2. Wireless connection of this sensor to a LabQuest 2 requires a Go Direct Bluetooth Adapter when used with some older LabQuest 2 models.

InterfaceSoftware
Graphical Analysis for iOS
NO INTERFACE REQUIREDFull Support
LabQuest 3Full Support 1 2
LabQuest 2
(Discontinued)
Full Support 1 2 3

COMPATIBILITY NOTES

  1. Connect this sensor directly to a supported mobile device via a wireless Bluetooth® connection for best results.
  2. Mobile devices can only connect to LabQuest 2 or LabQuest 3 via Wireless Data Sharing.
  3. Wireless connection of this sensor to a LabQuest 2 requires a Go Direct Bluetooth Adapter when used with some older LabQuest 2 models.

InterfaceSoftware
Graphical Analysis for Android
NO INTERFACE REQUIREDFull Support
LabQuest 3Full Support 1 2
LabQuest 2
(Discontinued)
Full Support 1 2 3

COMPATIBILITY NOTES

  1. Connect this sensor directly to a supported mobile device via a wireless Bluetooth® connection for best results.
  2. Mobile devices can only connect to LabQuest 2 or LabQuest 3 via Wireless Data Sharing.
  3. Wireless connection of this sensor to a LabQuest 2 requires a Go Direct Bluetooth Adapter when used with some older LabQuest 2 models.

What's Included

  • Go Direct® Pyranometer
  • Pyranometer lens cover
  • Micro USB Cable