Navigation

Go Direct® Voltage Probe

Go Direct® Voltage Probe

£125.00 ex VAT | £150.00 Inc VAT

The Go Direct Voltage Probe combines a wide input voltage range and high precision, making it an excellent choice for investigations of both AC/DC circuits and electromagnetism. It directly connects wirelessly via Bluetooth® or wired via USB to your platform.

Available to Order

Contact via Whatsapp 01530 832500

Description

The Go Direct Voltage Probe combines a wide input voltage range and high precision, making it an excellent choice for lab investigations of both AC/DC circuits and electromagnetism. Use this differential probe to measure the voltage in simple circuits, to study basic principles of electrochemical cells, or to investigate the resistivity of different metals.

With a range of ±15 V, this system is ideal for use in “battery and bulb” circuits. Go Direct Voltage is capable of kHz sampling and mV resolution, so you can also use it to capture more difficult electric potentials, such as the electromagnetic field induced in a coil by a moving magnet. This single sensor can take the place of several voltmeters in your classroom.

The Go Direct Voltage Probe can be used in a variety of experiments:

  • Measure potential difference at various places in series and parallel circuits.
  • Investigate Ohm’s law in simple circuits.
  • Measure the voltage across a capacitor in RC and RLC circuits.
  • Explore Faraday’s law and induced EMFs in a coil of wire.

Rechargeable Battery—Ready When You Are

The robust rechargeable battery offers long battery life and provides always-ready operation when using the sensor wirelessly. Monitor battery life directly from our free Vernier Graphical Analysis™ app, as well as Vernier Graphical Analysis Pro and LabQuest® 3. Should the battery run low, simply connect the sensor to the charging cable and keep on collecting–no interruptions or inconvenience to you or your students.

Wireless or Wired—The Flexibility to Choose

Our Go Direct sensors connect directly to your mobile device, Chromebook™, or computer using our free Vernier Graphical Analysis™ app–no additional equipment or software purchases are necessary. Go Direct sensors can be used wired via USB or wirelessly via Bluetooth® wireless technology, allowing you to choose the solution best for your classroom or laboratory.

Experiments

Physical Science with Vernier

  • Lemon “Juice”
  • Lead Storage Batteries

Chemistry with Vernier

  • Establishing a Table of Reduction Potentials: Micro-Voltaic Cells
  • Lead Storage Batteries

Agricultural Science with Vernier

  • Lemon “Juice”

Middle School Science with Vernier

  • Lemon “Juice”

Investigating Chemistry through Inquiry

  • Investigating Voltaic Cells

Advanced Chemistry with Vernier

  • Electrochemistry: Voltaic Cells

Specification

  • Input voltage range: ±15.0 V
  • Maximum voltage on any input: ±15 V
  • Typical resolution: 0.5 mV
  • Power: Internal rechargeable battery or USB connection
    Connections:
  • Wireless: Bluetooth
  • Wired: USB

Requirements

Software Requirements

InterfaceLabQuest App
LabQuest 3Full Support
LabQuest 2
(Discontinued)
Full Support 1
Vernier LabQuest
(Discontinued)
Incompatible

COMPATIBILITY NOTES

  1. Wireless connection of this sensor to a LabQuest 2 requires a Go Direct Bluetooth Adapter when used with some older LabQuest 2 models.

]

InterfaceGraphical Analysis App for Computers
NO INTERFACE REQUIREDFull support 1
LabQuest 3Full support 2
LabQuest 2
(Discontinued)
Full support 2 3

COMPATIBILITY NOTES

  1. For Bluetooth® connectivity, only computers running Windows 10 or Mac OS X 10.10 or newer are supported. The computer must also have a compatible Bluetooth 4.0+ radio.
  2. Connect this sensor directly to a computer or Chromebook via a USB or wireless Bluetooth® connection for best results. Alternatively, this sensor is fully supported when used with LabQuest 2 or LabQuest 3 when the LabQuest is connected to a computer or Chromebook via Wireless Data Sharing.
  3. Wireless connection of this sensor to a LabQuest 2 requires a Go Direct Bluetooth Adapter when used with some older LabQuest 2 models.

InterfaceGraphical Analysis for Chrome
NO INTERFACE REQUIREDFull Support
LabQuest 3

Full Support 1
LabQuest 2
(Discontinued)
Full Support 1 2

COMPATIBILITY NOTES

  1. Connect this sensor directly to a computer or Chromebook via a USB or wireless Bluetooth® connection for best results. Alternatively, this sensor is fully supported when used with LabQuest 2 or LabQuest 3 when the LabQuest is connected to a computer or Chromebook via Wireless Data Sharing.
  2. Wireless connection of this sensor to a LabQuest 2 requires a Go Direct Bluetooth Adapter when used with some older LabQuest 2 models.

InterfaceSoftware
Graphical Analysis for iOS
NO INTERFACE REQUIREDFull Support
LabQuest 3Full Support 1 2
LabQuest 2
(Discontinued)
Full Support 1 2 3

COMPATIBILITY NOTES

  1. Connect this sensor directly to a supported mobile device via a wireless Bluetooth® connection for best results.
  2. Mobile devices can only connect to LabQuest 2 or LabQuest 3 via Wireless Data Sharing.
  3. Wireless connection of this sensor to a LabQuest 2 requires a Go Direct Bluetooth Adapter when used with some older LabQuest 2 models.

InterfaceSoftware
Graphical Analysis for Android
NO INTERFACE REQUIREDFull Support
LabQuest 3Full Support 1 2
LabQuest 2
(Discontinued)
Full Support 1 2 3

COMPATIBILITY NOTES

  1. Connect this sensor directly to a supported mobile device via a wireless Bluetooth® connection for best results.
  2. Mobile devices can only connect to LabQuest 2 or LabQuest 3 via Wireless Data Sharing.
  3. Wireless connection of this sensor to a LabQuest 2 requires a Go Direct Bluetooth Adapter when used with some older LabQuest 2 models.

What's Included

  • Go Direct Voltage Probe
  • Micro USB Cable