Navigation

Go Direct® ORP Sensor

Go Direct® ORP Sensor

£168.00 ex VAT | £201.60 Inc VAT

The Go Direct ORP (Oxidation-Reduction Potential) Sensor measures the ability of a solution to act as an oxidizing or reducing agent. It directly connects wirelessly via Bluetooth® or wired via USB to your platform.

Available to Order

Contact via Whatsapp 01530 832500

Description

Use the Go Direct ORP Sensor to measure the ability of a solution to act as an oxidizing agent and to quantify ion activity. This sensor measures the capacity of a solution to either release or accept electrons from chemical reactions.

This sensor is comprised of an ORP electrode connected to a Go Direct Electrode Amplifier via a BNC connector. This design enables you to use the Go Direct Electrode Amplifier with other Vernier electrodes, such as the pH Electrode, Flat pH Electrode, ORP Electrode, ISE electrode, or a third-party electrode.

The Go Direct ORP Sensor can be used in a variety of experiments:

  • Determine the equivalence point of an oxidation-reduction titration.
  • Measure the oxidising ability of chlorine in swimming pools.
  • Investigate the ORP of drinking water.

Rechargeable Battery—Ready When You Are
The Go Direct robust rechargeable battery offers long battery life and provides always-ready operation. Monitor battery life directly from our free Graphical Analysis™ app. Should the battery run low, simply connect the sensor to the charging cable and keep on collecting—no interruptions or inconvenience to you or your students.

Wired or Wireless—The Flexibility to Choose
Our Go Direct™ ORP Sensor connects directly to your mobile device, Chromebook, or computer using our free Graphical Analysis™ 4 app—no additional equipment or software purchases are necessary. Go Direct sensors can be used wired via USB or wirelessly via Bluetooth, allowing you to choose the solution best for your classroom or laboratory.

Experiments

Advanced Chemistry with Vernier

  • An Oxidation-Reduction Titration: The Reaction of Fe2+ and Ce4+
  • Potentiometric Titration of Hydrogen Peroxide

Investigating Chemistry through Inquiry

  • Oxidation-Reduction Titrations

Specification

ORP Electrode

  • Accuracy: ±2% FS
  • Type: Sealed, gel-filled, polycarbonate body, Ag/AgCl reference, single junction
  • Storage solution: pH-4/KCl solution (10 g KCl in 100 mL buffer pH-4 solution)
  • ORP element: 99% pure platinum band sealed on a glass stem
  • Shaft diameter: 12 mm OD
  • Impedance: ~20 kΩ at 25ºC

Electrode Amplifier

  • Units: mV
  • Input range: ±1000 mV
  • Connections: Wireless: Bluetooth or Wired: USB

Requirements

Software Requirements

InterfaceLabQuest App
LabQuest 3Full Support
LabQuest 2
(Discontinued)
Full Support 1
Vernier LabQuest
(Discontinued)
Incompatible

COMPATIBILITY NOTES

  1. Wireless connection of this sensor to a LabQuest 2 requires a Go Direct Bluetooth Adapter when used with some older LabQuest 2 models.

]

InterfaceGraphical Analysis App for Computers
NO INTERFACE REQUIREDFull support 1
LabQuest 3Full support 2
LabQuest 2
(Discontinued)
Full support 2 3

COMPATIBILITY NOTES

  1. For Bluetooth® connectivity, only computers running Windows 10 or Mac OS X 10.10 or newer are supported. The computer must also have a compatible Bluetooth 4.0+ radio.
  2. Connect this sensor directly to a computer or Chromebook via a USB or wireless Bluetooth® connection for best results. Alternatively, this sensor is fully supported when used with LabQuest 2 or LabQuest 3 when the LabQuest is connected to a computer or Chromebook via Wireless Data Sharing.
  3. Wireless connection of this sensor to a LabQuest 2 requires a Go Direct Bluetooth Adapter when used with some older LabQuest 2 models.

InterfaceGraphical Analysis for Chrome
NO INTERFACE REQUIREDFull Support
LabQuest 3

Full Support 1
LabQuest 2
(Discontinued)
Full Support 1 2

COMPATIBILITY NOTES

  1. Connect this sensor directly to a computer or Chromebook via a USB or wireless Bluetooth® connection for best results. Alternatively, this sensor is fully supported when used with LabQuest 2 or LabQuest 3 when the LabQuest is connected to a computer or Chromebook via Wireless Data Sharing.
  2. Wireless connection of this sensor to a LabQuest 2 requires a Go Direct Bluetooth Adapter when used with some older LabQuest 2 models.

InterfaceSoftware
Graphical Analysis for iOS
NO INTERFACE REQUIREDFull Support
LabQuest 3Full Support 1 2
LabQuest 2
(Discontinued)
Full Support 1 2 3

COMPATIBILITY NOTES

  1. Connect this sensor directly to a supported mobile device via a wireless Bluetooth® connection for best results.
  2. Mobile devices can only connect to LabQuest 2 or LabQuest 3 via Wireless Data Sharing.
  3. Wireless connection of this sensor to a LabQuest 2 requires a Go Direct Bluetooth Adapter when used with some older LabQuest 2 models.

InterfaceSoftware
Graphical Analysis for Android
NO INTERFACE REQUIREDFull Support
LabQuest 3Full Support 1 2
LabQuest 2
(Discontinued)
Full Support 1 2 3

COMPATIBILITY NOTES

  1. Connect this sensor directly to a supported mobile device via a wireless Bluetooth® connection for best results.
  2. Mobile devices can only connect to LabQuest 2 or LabQuest 3 via Wireless Data Sharing.
  3. Wireless connection of this sensor to a LabQuest 2 requires a Go Direct Bluetooth Adapter when used with some older LabQuest 2 models.

What's Included

  • Go Direct ORP (includes Go Direct Electrode Amplifier)
  • Micro USB Cable
  • pH storage solution bottle with pH Storage Solution